Structured cabling is the permanent cable from a patch panel port to a wall outlet. In CABVIX outlets always come from patch panels — every panel port is either cabled to an outlet, spare, or not yet identified.
Panel first: on the Outlets screen, select ports on the panel faceplate (shift-click for a range), then choose Single, Double, Triple or Quad — or split the selection into several outlets. Mark ports with no cable as spare.
Label every outlet quickly: press ✎ Quick edit all outlets (top of the Outlets tab, or above an outlet list). Every outlet on the rack is in one list, sorted by ID. Type the description and location straight down — Enter moves to the next outlet — use Fill blanks ↓ to copy an entry into the empty boxes below it, and All labelled to set every status at once. Nothing is saved until you press Save.
A device plugged into an outlet: when a device plugs into a wall outlet with a lead — or into an outlet fitted inside the rack, like a UPS network card plugged into an outlet in the back of the cabinet — open Patching, click the device's port, then plug it into an outlet… and pick the outlet. It's recorded as the outlet's plugged-in device (not a rogue cable), the port shows as in use, and Trace, Topology and Blast Radius follow it through the outlet's cabling and panel port to whatever that port is patched to. Click the port again to see the path or Unplug it.
Outlet first (surveying an existing site): use Map an outlet from the field. Name the outlet and where it is, put your toner on each jack, and tap the port that beeps.
An outlet that runs to ports on two panels: use Continue on another panel →.
Tie cables between patch panels: structured cabling from the back of ports on one panel to the back of ports on another — e.g. a small wall-mount panel in another spot. Add the other spot as a rack (a 1–2U wall-mount open frame or vertical wall mount) with its patch panel, then on either panel select the port(s) and press ⇄ Tie to another panel…: pick the other panel and its first port — the rest pair up in order — with the cable, an optional length and a label (each cable gets -01, -02…). Both ends show TIE. Patch the front of each end as usual; Trace follows a wall outlet at the small panel through the tie to the switch in the main rack, and Blast Radius and topology follow it too. Ties are also listed on the Links tab, where Edit changes the cable, length or notes, or removes them.
Pass-through ports: for a device inside the rack — a PC on a shelf, the network port on the back of a UPS — swap that keystone for a pass-through. Select the port(s) on the faceplate and press ⇄ Pass-through to a device…, then pick the device and its port (several ports go to the next free ports in turn). Patch the switch into the panel's front as usual; the rear lead to the device shows teal, and Trace, Blast Radius, topology and the lead list follow it through. A pass-through port has no outlet and is never “not yet identified”. Select it again to change or remove it.
Ports still “not yet identified” count as a documentation gap in Health until you map them or mark them spare.
Damaged ports: select a port (or a run) and choose ⚠ Mark damaged, with a note of what's wrong if you like. It shows striped red on the faceplate and on the Patching tab, and anyone patching into it is warned first. Once it's been re-terminated or the panel replaced, select it and choose ✓ Mark repaired. Both are recorded in the rack's History.
Trace an outlet is the second half of this tab — switch to it at the top to follow any outlet through to its switch port.
Map an existing outlet from the field
This is the same guide that’s built into CABVIX (the ? button on every screen). Want to try it? The live demo is the real app with sample data.