CABVIX

CABVIX / Help guide / Documenting a site

HELP · DOCUMENTING A SITE

Racks and hardware

Add hardware — select, configure, drag into the rack. Recorded in the CABVIX app.

The rack view is a front (and rear) elevation. + Add hardware opens a panel on the right in three steps — Select it, Configure it (label, height, ports) and Place it: drag the card onto the rack — the spot turns green where it fits and shows the ID it will get. Clicking an empty RU also opens the panel, aimed at that RU — press Add to put it there (otherwise Add uses the top-most free space). While the panel is open, clicking any empty RU drops the item straight in. The panel stays open so you can add the next item straight away. (On a phone, tapping an empty RU opens a Place hardware form instead.) Multi-RU devices draw as one card.

Adding a rack: on the site page use + Add rack, give it a name and tap a common rack (42U floor cabinet, 12U wall cabinet, 2-post frame, an 8- or 24-port wall-mount patch panel…) — done. A wall-mount patch panel is added with its keystone panel already in it (6 to 24 ports — pick the count under Set it up in detail), ready for outlets or tie cables back to the main rack. For anything else, choose Set it up in detail…: pick what kind it is — floor cabinets (enclosed, half-height, deep server, acoustic, mobile), wall-mounted (wall cabinet, hinged swing-frame, open frame, vertical wall mount, 10-inch mini cabinet) or open frame & special (2-post, 4-post, outdoor, recorder lockbox). Then set its height (any 1–52 RU, or tap a stock size), width, depth, rails (2- or 4-post, Rear posts on or off, the depth between the rails), side (0U) spaces, doors and how it's mounted. The preview is drawn to scale. A rack with no rear posts is front-mount only, so there's no rear elevation to place gear on.

The rack's build is set when it's added. Edit rack (✎ next to its name) changes the name, code, RU numbering and details like make/model and load rating — and the Room it's in: pick another room at the site (or + A new room…) to move it; everything on it comes too. Made it the wrong size, or the rack itself was swapped? Use Change size or type… (in Rack tools ▾ → This rack, or in Edit rack): change the height, size or type, choose whether positions are kept counted from the bottom or the top, see what moves to free space, then confirm. It's the same rack record, so leads, cabling, power, links, plan pins and the rack's QR sticker carry over; a restore point is saved first and the old rack stays in History. Devices whose ID changes show their printed labels as out of date.

3D view (Pro): press 3D view in the rack toolbar (also in the sidebar Tools, Rack tools ▾ → 3D view and on Room view). It draws the rack straight from its record — any rack you've already built, nothing to set up: every device in its RU in its maker's colours with the sticker you printed, the patch leads with real plug ends, the power cords at the back and a depth check against the cabinet. Routed leads start hanging loose — Tidy up with Velcro dresses them along their routes and straps the bundle; Direct ignores the routes. Open door, Side and Rear (cut-aways) and Close-up change the view; drag to turn it, scroll or pinch to zoom (it zooms towards wherever you point), ▲ ▼ on the right (hold to glide), the ↑ ↓ keys or Shift + scroll to move up and down a tall rack, right-drag (two fingers on a phone) to slide sideways, Save image for a picture. Room stands it in its room from Room view — with a power point inside the back of the cabinet when that's where it is (Power point takes you there). A rack not placed in Room view yet is shown in a sample room. Nothing you do in the 3D view changes the record. And in the room, try Just for fun…

Name / role: each device is named by what it does — picking a model fills in its role (e.g. Network switch, Firewall, Patch panel); change it to something more specific like Core switch or Level 2 access. The rack shows it next to the device's ID, with the make and model underneath.

Favourites: tap the ☆ on any model to keep it at the top of the list — or use ★ Favourites to see only yours. Favourites are just for you and follow you on any device.

The hardware library has over 2,100 real models — switches, firewalls, gateways, rack servers, patch panels, fibre, UPSs, PDUs, NAS, NVRs and access control, PA amplifiers and AV processors, console servers and KVMs, 4G/5G failover routers, NBN, carrier modems and Starlink gear. Search by model number (“c9200l 24p”, “usw pro max”, “smt1500”) or narrow it down by type — Servers & storage, AV, PA & voice and Security have their own chips (PA amplifiers, mixers, zone selectors, bell timers and AV processors are their own type, PA & AV — not servers) — brand, PoE or SFP uplinks. Picking a model fills in its ports, SFP uplinks, power outlets and height, and shows its specifications; you can still change anything — changes are marked edited from the catalogue with a Reset. Models marked Check specs haven't been checked against the manufacturer's datasheet yet, so confirm them on the device. Something missing? Add it as Custom / not listed and tick Save as a company model so your whole team can pick it next time. Spot a wrong number? Use Suggest a correction under the specifications.

Every device gets an ID automatically, like A-PP08 — rack A, patch panel, lowest RU 8. See Device and outlet IDs for how these are built.

The bar above the rack shows its fit-out: Hardware → Power → Structured cabling → Patching → Labels. Click a step to go to it; Labels opens Label Studio with this rack's stickers ticked, ready to print or order printed.

Small devices that sit on a shelf (a modem, an NVR) go on the shelf rather than taking RU of their own.

The rack shows every RU. On a big, sparse rack use Fold empty space in the toolbar above the rack to fold runs of empty RUs into one band — click a band to open it again (Fold ▴ folds it back). Only RUs that are empty on both faces fold, so the front and rear always line up RU for RU.

Fit-out strip: one line above the rack shows the steps (Hardware → Power → Structured cabling → Patching → Labels), where you're up to, and the next action — click a step to go to it.

Toolbar: + Add hardware, 3D view, Photo, Cables, ⚡ Power, Fold empty space tick. Patching is the Patching tab.

Cables: in the toolbar above the rack, Cables — Off / Bundled / One lead / Every lead draws the patch leads on the rack. Bundled keeps a full rack readable: where leads between the same two devices share a path they become one trunk with a count and length (e.g. 16 × 0.5 m), and each lead's own drop to its port stays a thin line. One lead shows just one: click any patched port to see the path of its lead, its colour and length. Every lead draws each one in its lead colour — hover for details, click one to edit it. Lead list (Pro; under Leads ▾ and in Rack tools) lists every lead with its length and colour, with a CSV download — handy for knowing what to bring.

Power cords (Pro plan): ⚡ Power (next to Cables, when the rack has power recorded) draws each power feed on the rear elevation (power inlets are at the back) as a dashed cord from the UPS or PDU outlet, down the rack's right-hand side, to the device it feeds — front-mounted devices show there as a “— back” band on their RUs — coloured by the unit feeding it, so two supplies on a dual-PSU device are easy to check. In One lead view, click a UPS/PDU outlet or a device's ⚡ to see its whole power chain with plug types and lengths. Power cords are in the Lead list too: the type and length come from the feed's cable reference (e.g. “IEC C13-C14, 2m”), otherwise they're estimated.

Quick patch (toolbar above the rack) is the fast way to patch: drag from a port to the port it goes to and let go — it's saved straight away (Undo is on the message). Carry the lead out past the left or right edge of the rack on the way and it's routed down that side; straight across takes the automatic route through the nearest cable manager. No need to hold the button: click a port and the lead follows your mouse — take it to the edge, up or down, back in, and click the port it goes to (click the first port again, or press Esc, to put it down). Either way the turns pin themselves at the nearest cable manager or gap between units, and you hear the plug click in (🔊 in the toolbar turns that off). The colour chosen in the toolbar is used for each new lead. As soon as a lead is saved a small pop-up opens beside it — change its colour, route (Auto · Left · Right · Draw), cable type, use the same route for the other leads between those two units, or Unpatch. It never gets in the way: just drag the next one. Re-patching: click (or drag) a patched port and that end of the lead lifts out — the other end stays plugged in — then click the port it goes to now; it keeps its colour. Click it back into the same port to keep it there and open its pop-up (colour, route, cable). Esc puts a lifted lead back; Esc again or Done finishes. Panel-to-panel cross-connects, rogue cables and ports with a network link still open their own dialog.

Routing a lead (Pro plan — the Trial includes it): the quickest way is to drag the lead the way it runs with Quick patch (see above) — or, for a lead that's already patched, turn on Quick patch, click its port and pick Auto, Left or Right in its pop-up. To draw every corner yourself, pick ✎ Draw there (or Redraw route in the One lead view), then click each place the lead changes direction and finish on the far port. The tidiest way is usually: down into the cable manager under the panel, out to the side channel, down the side of the rack, back in through the cable manager over the switch, then across to the switch port. Clicks snap to cable managers and the side channels. When you finish, CABVIX offers to use the same route for the other leads between those two devices. Undo a point with Undo point or Esc. Leads you haven't drawn follow an automatic route through the nearest cable manager.

How units look: each unit is drawn as its front — the maker's finish (UniFi silver, most others black), its ports as squares laid out the way the real unit has them (SFP ports too), and its touchscreen, drive bays or vents. A port in a colour has a patch lead of that colour in it. There's no writing on the units: the unit's ID is on the little QR sticker at its right — solid when its label has been printed, dashed when it hasn't yet, with an amber ring when the printed label is out of date. Hover the sticker for the unit's name, model, RU, ports in use, power and label; click it (or ⓘ in the top-left corner) for every port and connection. The ⚡ under ⓘ is lit when the unit's power is recorded.

Click a device to edit, Move…, Duplicate or Replace it. Drag a device to move it; hold Ctrl while you drag (Option on a Mac) to drop a copy on the RU you let go on — the quickest way to fill a rack with panels or managers. A copy is the same model and settings with its own new ID, and it isn't patched, powered or labelled yet. Duplicate puts the copy in the nearest free space.

Finding your way: the breadcrumb at the top (client › site › room › rack) takes you back up — click the site to see every room with its racks. Under the rack's name is one line of facts (size, RU used, devices, ports in use) and, if anything is missing, an amber gaps to fix link. The ✎ next to the name edits the rack.

Tabs: Rack (the elevations) · Patching (patch leads) · Outlets (structured cabling, with Trace an outlet inside it) · Power · Links (uplinks, wireless, WAN and VPN that leave the rack) · History (every change, who and when) · Evidence & sign-off (photos, test results, commissioning). A greyed tab tells you what to add first.

Rack tools ▾ (top right) holds everything else for this rack, grouped: Labels & access (labels for this rack — print or order, the rack QR sticker, give a contractor access), On site (lead list, guided fixes sent), What if (if this rack failed… — Blast Radius), Records (rack report, import CSV, duplicate rack) and This rack (core rack, RU numbering, edit details). Guided fix next to it sends someone on site step-by-step pictures for a quick fix (see Guided fixes).

Change a rack's size or type — the hardware comes across

Change a rack's size or type — the hardware comes across. Recorded in the CABVIX app.

See a rack in 3D — tidy the leads, look round the back

See a rack in 3D — tidy the leads, look round the back. Recorded in the CABVIX app.

See the patch leads on the rack

See the patch leads on the rack. Recorded in the CABVIX app.

This is the same guide that’s built into CABVIX (the ? button on every screen). Want to try it? The live demo is the real app with sample data.